Multifunctional
Multifunctional
Article summary
Did you find this summary helpful?
Thank you for your feedback
Multifunctional Node
Basic Configuration
In the Rayven Workflow
- Select Functions
- Drag the MultiFunctional node to the left hand side of the canvas.
- Connect the MultiFunctional node to your input node
- Double click in the node for the configuration layer to open up.
Define the MultiFunctional node
- Node Name: Provide a name that describes the node purpose or data source.
- Field Name: Provide the field name of the JSON object where value is stored
- Function: Sum, Average, Min, Max, Count, Last Value
- Interval: Provide number/integer for all function selection except Last Value
- Interval Unit: Seconds, Minutes, Hours, Days, Weeks (Starts on Sunday), Weeks (Starts on Monday), Months,
- Output Field Name: Provide new key for output
- Levels Up:
- When checked
- 0 level: The direct device group that the entering device belongs to (Room Level)
- 1 level: The parent group of the direct device group (Floor Level)
- 2 levels: The parent of the parent of the direct device group (Building Level)
- When unchecked, the calculations will be performed on the device (same as in charts)
- When checked
- Decimal Precision: Provide an integer to define number of decimal places of output