Multifunctional

      Multifunctional


        Article summary

        Multifunctional Node

        Basic Configuration

        In the Rayven Workflow 

        1. Select Functions
        2. Drag the MultiFunctional  node to the left hand side of the canvas.
        3. Connect the MultiFunctional  node to your input node
        4. Double click in the node for the configuration layer to open up.

        Define the MultiFunctional node

        1. Node Name: Provide a name that describes the node purpose or data source.
        2. Field Name: Provide the field name of the JSON object where value is stored
        3. Function: Sum, Average, Min, Max, Count, Last Value
        4. Interval: Provide number/integer for all function selection except Last Value
        5. Interval Unit: Seconds, Minutes, Hours, Days, Weeks (Starts on Sunday), Weeks (Starts on Monday), Months,
        6. Output Field Name: Provide new key for output
        7. Levels Up:
          1. When checked
            1. 0 level: The direct device group that the entering device belongs to (Room Level)
            2. 1 level: The parent group of the direct device group (Floor Level)
            3. 2 levels: The parent of the parent of the direct device group (Building Level)
          2. When unchecked, the calculations will be performed on the device (same as in charts)
        8. Decimal Precision: Provide an integer to define number of decimal places of output